Disc Brake Use And Installation Precautions

Notes on installation

1. Please use the electromagnetic brake when there is no moisture or oil. If there is moisture or oil on the friction parts, the friction torque will be greatly reduced, and the braking sensitivity will be worse. In these cases, please add a cover.

2. When using in a dusty place, please put all the brakes in the box. Electromagnetic brakes up to 60KGM can be used upright, even for higher models.

3. Please use JIS0401 H6 or JS6 for the length of the long shaft used to install the brake. Use one of the keys for mounting the shaft as specified in JIS B1301-1959.

4. Considering thermal expansion and other factors, please select the thrust of the mounting shaft below 0.2mm.

5. When installing, please adjust the suction gap to within 20% of the specified value.

6. Keep the bracket light and do not use excessive pressure on the bearing of the brake.

7. For screws for assembly, please use a spring metal sheet, adhesive, etc. to prevent loosening.

8. At the same time, the lead frame is maintained by the frame on the machine side, and the terminal board is used for reliable connection.

Maintenance method

In order to ensure the uninterrupted operation of the electromagnetic brake, it must be maintained and maintained frequently:

1. Lubricant is often added to the movable part of the electromagnetic brake.

2. Regularly check the length of the armature stroke. Because during the operation of the brake, the stroke length of the armature will increase due to the wear of the profile. When the armature stroke length does not reach the normal value, it must be adjusted to restore the minimum gap between the brake surface and the turntable. If the armature stroke length increases above normal, suction may be greatly reduced.

3. If the worn brake surface is replaced, the minimum clearance between the brake surface and the turntable should be readjusted appropriately.

4. Frequently check the tightness of the bolts, especially tighten the bolts of the electromagnet, the bolts of the electromagnet and the shell, the bolts of the yoke, the bolts of the solenoid coil, and the wiring bolts.

5. Regularly check the mechanical wear of the moving parts, and remove the dust, hair and dirt on the surface of the electromagnet parts.

Table of Contents